AED Pad & Battery Compatibility Chart

Every AED model we sell in Canada, with the exact pads and battery that fit it. Ordering the wrong pads is the most common mistake in this category — this page exists so it doesn't happen to you.

The five mistakes we see most often

  • Philips FRx pads on an OnSite. Both are "Philips HeartStart pads." Philips states plainly that FRx SMART Pads II are not for use with HS1, OnSite or Home units. This is the single most common wrong order in Canada.
  • Uni-padz on an AED Plus. CPR-D-padz fit both the AED Plus and the AED 3. Uni-padz fit the AED 3 only. They look similar and both have a CPR sensor.
  • Pedi-padz II on an older AED Plus. Your AED Plus must carry the pediatric-capable symbol. Units without it will not work with Pedi-padz II and need a ZOLL upgrade kit first.
  • Defibtech "1xx" vs "2xxx" parts. DDP-100 and DDP-200P fit the original Lifeline. DDP-2001 and DDP-2002 fit the VIEW/ECG/PRO. They are not interchangeable.
  • HeartSine Pad-Pak numbering. PAD-PAK-01, -03 and -07 are adult. PAD-PAK-02 and -04 are pediatric. The numbers don't run in order — trust the colour: grey is adult, pink is pediatric.

Full compatibility chart

Part numbers are the manufacturer's own. Where a manufacturer sells the same part under two numbers, both are listed.

AED model Adult pads Pediatric Battery Pad life Battery life
ZOLL AED Plus CPR-D-padz 8900-0800-01
Stat-padz II 8900-0801-01
Pedi-padz II 8900-0810-01
unit must be pediatric-capable
8000-0807-01
10 × Type 123A
5 yr (CPR-D)
2 yr (Pedi)
5 yr standby
ZOLL AED 3 CPR Uni-padz III 8900-000280
also accepts CPR-D-padz
Uni-padz + Child button
or Pedi-padz II
8000-000696 5 yr 5 yr call to confirm
Philips HeartStart OnSite / HS1 M5071A
(861291-ABA)
M5072A Infant/Child cartridge M5070A
(989803121381)
2 yr call to confirm 4 yr standby
Philips HeartStart FRx 989803139261
SMART Pads II
989803139311
Infant/Child key — pads unchanged
M5070A — same as OnSite 2 yr 4 yr standby
Defibtech Lifeline (DDU-100/120) DDP-100 DDP-200P DBP-1400 5 yr
DBP-2800 7 yr
2 yr 5 / 7 yr
Defibtech VIEW / ECG / PRO DDP-2001 DDP-2002 blue connector DBP-2003 2 yr 4 yr
HeartSine samaritan 350P / 360P / 500P PAD-PAK-01 grey
PAD-PAK-07 aviation
PAD-PAK-02 pink Combined — the Pad-Pak is the battery 4 yr from manufacture (single expiry)
Cardiac Science Powerheart G5 XELAED001C
XELAED002C with CPR feedback
XELAED003C XBTAED001A call to confirm call to confirm
Cardiac Science Powerheart G3 9131-001 9730-002 9146-302
9145-301 G3 Pro only
call to confirm call to confirm
LIFEPAK CR2 11101-000021 QUIK-STEP — one set serves adult and child; Child Mode is a button on the device 11141-000165 4 yr 4 yr standby
LIFEPAK CR Plus / EXPRESS Sold only inside a CHARGE-PAK kit: 11403-000002 (1 set) or 11403-000001 (2 sets).
Pediatric: 11101-000016
CHARGE-PAK — replaced with the pads 2 yr 2 yr
LIFEPAK 1000 11996-000017 EDGE / QUIK-COMBO 11101-000016 11141-000100 call to confirm 5 yr standby

Part numbers are taken from manufacturer documentation and manufacturer web stores. Where a value is marked call to confirm, we have not confirmed it from a primary manufacturer source — call us and we will confirm it before you order.

Common questions

How do I know when my pads expire?

Every pad package carries a printed expiry date, usually on the foil pouch and again on the outer box. Most AEDs will also chirp or show a service indicator once pads pass their date. Pads expire whether or not the device has ever been used — the gel dries out.

Can I use expired pads in an emergency?

Yes — using expired pads is better than doing nothing, because the alternative is no defibrillation at all. But expired gel conducts poorly and the shock may be less effective, so they should be replaced immediately afterwards. Expired pads are not a substitute for in-date ones.

Do I need separate pediatric pads?

It depends on the model. Philips FRx and LIFEPAK CR2 switch to pediatric energy with a key or a button and use the same pads. ZOLL, Defibtech, HeartSine and Cardiac Science all require physically different pediatric pads or cartridges. Check the chart above for yours.

My AED is discontinued. Can I still get parts?

Often yes. Call us at 1-877-851-0756 with the model and, if you can, the part number from the old pads. We can usually source consumables for older units, and if we genuinely can't, we'll tell you rather than sell you something that doesn't fit.

How do I stop this creeping up on me?

Ask us to put your units on expiry reminders. Send the model and purchase date and we'll email you ninety days before your pads or battery lapse, with a direct link to reorder the right part. It's free.

Still not sure? Call 1-877-851-0756 or email sales@shockshop.ca with your AED's make, model and — if you can find it — the part number printed on your current pads. We'd much rather spend two minutes confirming than have you order the wrong part for a life-safety device.

Manufacturers change specifications without notice. Where a part matters to a compliance decision, confirm against the manufacturer's own documentation or call us.